OBV5-C40-PV
Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules
Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)
Tried and tested fault-resistant Y circuit of the OBV6-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit.
Integrated d.c. fuse allows safe replacement of protection modules without arc formation.
Technical Parameters
| Model: OBV5-C40-PV | ||||||
| Network voltage | 500Vdc | 600Vdc | 800Vdc | 900Vdc | 1000 Vdc | |
| Max. operating voltage Uc | 530Vdc | 630Vdc | 840Vdc | 950Vdc | 1060 Vdc | |
| Nominal discharge current ln | 20kA | |||||
| Max. discharge current lmax | 40kA | |||||
| Protection level (at In) Up | 1.8kV | 2.5kV | 2.8kV | 3.0kV | 3.2kV | |
| Disconnector | ||||||
| Thermal Disconnector | Internal | |||||
| Mechanical characteristics | ||||||
| Connection | by screw terminals: 4-25 mm2 | |||||
| Disconnection indicator | 1 mechanical indicator by pole | |||||
| Mounting | symmetrical rail 35 mm | |||||
| Operating temperature | -40/+85°C | |||||
| Protection class | IP20 | |||||
| Standards compliance | ||||||
| NF EN 61643-11 France | Parafoudre Basse Tension - Essais Classe II | |||||
| IEC 61643-1 International | Low Voltage SPD - Test Class II | |||||
| EN 61643-11 Europe | Parafoudre Basse Tension - Essais Classe II | |||||
Feature&Benefits
-Easy installation or retrofit
-Din-rail mountable
-Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact
-IP20 finger-safe design
Visual indicator
-Small foot print
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):
| Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) |
Max Discharge Current |
Protection Level(KA~) | Response Time(ns) |
| DGM1(2)-D5 | 220/380 |
275/320 |
5 | 10 | 1.2 | ≤25 |
| DGM1(2)-D10 | 10 | 2 | 1.6 | |||
| DGM1(2)-C20 | 20 | 40 | 1.8 | |||
| DGM13-B30 | 30 | 60 | .2.2 | |||
| DGM3(4)-B40 | 10 | 80 | 2.4 | |||
| DGM(4)-B60 | 60 | 100 | 2.8 | |||
| DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Tip:How can we distinguish the quality of the lightning arrester?
1. It can be seen from the reaction time: determine whether the lightning arrester can respond in time and quickly discharge the lightning current.
2. It can be seen from the insertion loss: this refers to the installation of a lightning protector, the impact of this lightning protector on the line, the smaller the better
3. It can be seen from the number of impact resistance: determines the service life of the lightning arrester. Generally, the gas discharge tube will not drop after being placed for a period of time. If you want to check its quality, you can use an adjustable high-voltage DC power supply to test .
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.