Add to Cart
Risk of voltage surges
Electrical and electronic equipment is indispensablein the daily activities of today's businesses and
individuals. Such devices are connected to theelectricity grid, often exchanging data and signals
through communication lines and are usually sensitive
to disturbances.These interconnecting networksprovide a propagation path for overvoltages.
Protection against lightning and overvoltages not onlyensures the safety of people, goods and equipment,but also ensures continuity of installation
services.Overvoltage protection extends the life of theequipment by more than 20%, which significantlyreduces the volume of electronic waste. It also
reduces the power consumption of the installations,all of which translates into cost savings and
environmental sustainability.
OBVW
F type date line surge protection device OBVW is the series of devices for discharging transient overvoltages induced in coaxial lines. In accordance with IEC 61643-21. Coaxial format.
Suitable for the protection of radiofrequency transmission and reception equipment. By their nature, they are highly exposed to induced transient overvoltages (surges) associated with meteorological activity.
For BNC, F, N, TNC connectors.
Ideal for the protection of transmission and reception systems such as TV and radio antennas, closed circuit TV (CCTV), alarms, etc.
Technical and Parameters
OBVW- BNC/75C | OBVW- BNC/50C | OBVW- N/75C | OBVW- N/50C | OBVW- F/75C | OBVW- F/50C | |
Maximum Continuous Operating Voltage Uc (~) | DC68V / AC130V / AC280V | |||||
Nominal Discharge Current In (8/20µs)kA | 10kA | |||||
Maximum discharge current Imax (8/20µs)kA | 20kA | |||||
Maximum peak power (W) | <300 | |||||
Interface | BNC | N | F | |||
Voltage protection level (Up) | <600V | |||||
Bandwidth (MHz) | 0-3000 | |||||
Standing wave ratio, VSWR | ≤1.2 | |||||
Insertion Loss | ≤0.1db | |||||
Impedance(Ω) | 75Ω | 50Ω | 75Ω | 50Ω | 75Ω | 50Ω |
Advantage:
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current Imax(KA) | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 385/420 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Application SPD: